Before discussing the difference between ID Fan and
FD fan, we must understand why we require draft system. Draft system is
required for basically two purpose i.e. for providing the required quantity of
hot air to furnace for smooth combustion of fuel and secondly for removing the
flue gases from system i.e. furnace to atmosphere after filtering dust with the
help of electrostatic precipitators.
Let us come to the main discussion point.
ID fan
ID fan is basically mentioned here for Induced draft
fan and ID fan is always located between dust collector and chimney. ID fan
will take the hot flue gases from furnace via dust collector (dust separation
system or Fume Extraction system) and will deliver to chimney. ID fan will
handle the flue gases i.e. hot air.
ID fan will produce the pressure lower than the
atmospheric pressure in the system or we may say that ID fan will
produce the negative pressure in the furnace to remove the flue gases from furnace
via electrostatic precipitators and to push the flue gases to chimney.
Do not get confused about the dust collector system.
Dust collector system also designated as fume extraction system or dust
separation system. Somewhere we also used to electrostatic precipitators in
place of dust collector system for removing dust particle from flue gases for
maintaining the clean environment.
FD Fan
FD fan, which is mentioned here for forced draft
fan, is used basically for providing the required quantity of hot air to the
furnace for smooth and uniform combustion of fuel. FD fan will produce the
positive pressure inside the system i.e. furnace.
Let us look the below figure, where we can
understand the location of both types of fan.
Also look
Keep reading...
You can also find out
No comments:
Post a Comment