DIFFERENCE BETWEEN ID FAN AND FD FAN

Before discussing the difference between ID Fan and FD fan, we must understand why we require draft system. Draft system is required for basically two purpose i.e. for providing the required quantity of hot air to furnace for smooth combustion of fuel and secondly for removing the flue gases from system i.e. furnace to atmosphere after filtering dust with the help of electrostatic precipitators. 
Let us come to the main discussion point.

ID fan

ID fan is basically mentioned here for Induced draft fan and ID fan is always located between dust collector and chimney. ID fan will take the hot flue gases from furnace via dust collector (dust separation system or Fume Extraction system) and will deliver to chimney. ID fan will handle the flue gases i.e. hot air. 

ID fan will produce the pressure lower than the atmospheric pressure in the system  or we may say that ID fan will produce the negative pressure in the furnace to remove the flue gases from furnace via electrostatic precipitators and to push the flue gases to chimney. 

Do not get confused about the dust collector system. Dust collector system also designated as fume extraction system or dust separation system. Somewhere we also used to electrostatic precipitators in place of dust collector system for removing dust particle from flue gases for maintaining the clean environment.

FD Fan

FD fan, which is mentioned here for forced draft fan, is used basically for providing the required quantity of hot air to the furnace for smooth and uniform combustion of fuel. FD fan will produce the positive pressure inside the system i.e. furnace. 

Let us look the below figure, where we can understand the location of both types of fan.